Warning and Blocking Cables

СБВГ

GOST Р 51312-99
Model Design Number of Strands Wire Cross-Section, mm2 Purpose of Use
СБВГ A signal and blocking cable with copper strands: insulated with PE and sheathed with PVC plasticate. 3 - 30
3 - 42
0,8; 0,9; 1,0 For single installation in-doors, in dry ducts and tunnels, in corrosive environments, without mechanical impact on the cable.

СБВГнг

GOST Р 51312-99
Model Design Number of Strands Wire Cross-Section, mm2 Purpose of Use
СБВГнг The same cable and also sheathed with fire-resistant plasticate. 3 - 30
3 - 42
0,8; 0,9; 1,0 The same, but for batch installation.

СБВБГ

GOST Р 51312-99
Model Design Number of Strands Wire Cross-Section, mm2 Purpose of Use
СБВБГ The same cable and also sheathed with PVC plasticate and armored with two steel strips. 3 - 42
3 - 42
0,9 ; 1,0 For single installation in dry cable ducts, tunnels, manifolds, in places where cables may be exposed to mechanical impact, including insignificant tensile force.

СБВБГнг

GOST Р 51312-99
Model Design Number of Strands Wire Cross-Section, mm2 Purpose of Use
СБВБГнг The same cable and also sheathed with fire-resistant plasticate. 3 - 42
3 - 42
0,9; 1,0 The same, but for batch installation.

СБВБбШвнг

GOST Р 51312-99
Model Design Number of Strands Wire Cross-Section, mm2 Purpose of Use
СБВБбШвнг The same cable and also sheathed with fire-resistant PVC plasticate, armored with two steel strips, jacketed with fire-resistant PVC plasticate. 3 - 42
3 - 42
0,9 ; 1,0 The same, but in corrosive environments.

СБПБбШв

GOST Р 51312-99

Model Design Number of Strands Wire Cross-Section, mm2 Purpose of Use
СБПБбШв A signal and blocking cable with copper strands: insulated with PE, sheathed with PE, armored with two steel strips, jacketed in PVC plasticate hose. 3 - 42
3 - 42
0,9 ; 1,0 For installation in ducts, tunnels, manifolds, in plastic pipelines. For burying in soil when cable is not exposed to significant tensile force.

СБЗПБбШв

GOST Р 51312-99

Model Design Number of Strands Wire Cross-Section, mm2 Purpose of Use
СБЗПБбШв The same cable and also with water-blocking cable core filling. 3 - 42
3 - 42
0,9 ; 1,0 The same, but in high humidity.

СБПВГ

GOST Р 51312-99
Model Design Number of Strands Wire Cross-Section, mm2 Purpose of Use
СБПВГ A signal and blocking cable with copper strands: insulated with PE, sheathed with PE and armored with two steel strips. 3 - 42
3 - 42
0,9 ; 1,0 For installation in ducts, in places where cable may be exposed to mechanical impact, but not to tensile force.

СБПБ

GOST Р 51312-99
Model Design Number of Strands Wire Cross-Section, mm2 Purpose of Use
СБПВГ A signal and blocking cable with copper strands: insulated with PE, sheathed with PE and armored with two steel strips. 3 - 42
3 - 42
0,9 ; 1,0 For installation in ducts, in places where cable may be exposed to mechanical impact, but not to tensile force.

СБПБбШп

GOST Р 51312-99
Model Design Number of Strands Wire Cross-Section, mm2 Operating voltage Purpose of Use
СБПБбШп The same and also sheathed with PE material, armored with two steel strips, jacketed in PE hose. 3 - 42
3 - 42
0,9 ; 1,0 380 V AC, 50 Hz or 700 V DC. For installation in plastic pipelines. For burying in soil where cable may be exposed to mechanical impact, but not to tensile force.

СБЗПБ

GOST Р 51312-99
Model Design Number of Strands Wire Cross-Section, mm2 Purpose of Use
СБЗПБ The same cable and also with water-blocking cable core filling. 3 - 42
3 - 42
0,9 ; 1,0 The same, but in high humidity.

СБЗПБГ

GOST Р 51312-99
Model Design Number of Strands Wire Cross-Section, mm2 Operating voltage Purpose of Use
СБЗПБГ A signal and blocking cable with copper strands: insulated with PE, sheathed with PE, armored with two steel strips, and also with water-blocking cable core filling. 3 - 42
3 - 42
0,9 ; 1,0 380 V AC, 50 Hz or 700 V DC. For installation in ducts, in places where cables may be exposed to mechanical impact, but not to insignificant tensile force, and also in high humidity with level 0.9-1.0.

СБПу

GOST Р 51312-99
Model Design Number of Strands Wire Cross-Section, mm2 Operating voltage Purpose of Use
СБПу A signal and blocking cable with copper strands: insulated with PE, thick sheathed with PE. 3 - 42
3 - 42
0,9 ; 1,0 380 V AC, 50 Hz or 700 V DC. For installation in plastic pipelines. For burying in soil in corrosive environments without mechanical impact.

СБЗПу

GOST Р 51312-99
Model Design Number of Strands Wire Cross-Section, mm2 Purpose of Use
СБЗПу The same cable and also with water-blocking cable core filling. 3, 4, 5, 12, 16, 30, 33, 42 0,9 ; 1,0 The same, but in high humidity.

СБЗПУ(Э)

GOST Р 51312-99
Model Design Number of Strands Wire Cross-Section, mm2 Operating voltage Purpose of Use
СБЗПУ(Э) The same cable and also (shielded) with water-blocking cable core filling . 3 - 42
3 - 42
0,9 ; 1,0 380 V AC, 50 Hz or 700 V DC The same, but in high humidity.

СБЗПЭБпШп

GOST Р 51312-99
Model Design Number of Strands Wire Cross-Section, mm2 Operating voltage Purpose of Use
СБЗПЭБпШп A signal and blocking cable with copper strands: insulated with PE, sheathed with PE, shielded, armored with two steel strips, with corrosion protection, jacketed in a PVC hose, and also with water-blocking cable core filling. 3 - 42
3 - 42
0,9 ; 1,0 380 V AC, 50 Hz or 700 V DC For installation in ducts, tunnels, manifolds, in plastic pipelines. For burying in soil when cable is not exposed to significant tensile force, in high humidity.