GOST Р 51312-99 | ||||
Model | Design | Number of Strands | Wire Cross-Section, mm2 | Purpose of Use |
СБВГ | A signal and blocking cable with copper strands: insulated with PE and sheathed with PVC plasticate. | 3 - 30 3 - 42 |
0,8; 0,9; 1,0 | For single installation in-doors, in dry ducts and tunnels, in corrosive environments, without mechanical impact on the cable. |
GOST Р 51312-99 | ||||
Model | Design | Number of Strands | Wire Cross-Section, mm2 | Purpose of Use |
СБВГнг | The same cable and also sheathed with fire-resistant plasticate. | 3 - 30 3 - 42 |
0,8; 0,9; 1,0 | The same, but for batch installation. |
GOST Р 51312-99 | ||||
Model | Design | Number of Strands | Wire Cross-Section, mm2 | Purpose of Use |
СБВБГ | The same cable and also sheathed with PVC plasticate and armored with two steel strips. | 3 - 42 3 - 42 |
0,9 ; 1,0 | For single installation in dry cable ducts, tunnels, manifolds, in places where cables may be exposed to mechanical impact, including insignificant tensile force. |
GOST Р 51312-99 | ||||
Model | Design | Number of Strands | Wire Cross-Section, mm2 | Purpose of Use |
СБВБГнг | The same cable and also sheathed with fire-resistant plasticate. | 3 - 42 3 - 42 |
0,9; 1,0 | The same, but for batch installation. |
GOST Р 51312-99 | ||||
Model | Design | Number of Strands | Wire Cross-Section, mm2 | Purpose of Use |
СБВБбШвнг | The same cable and also sheathed with fire-resistant PVC plasticate, armored with two steel strips, jacketed with fire-resistant PVC plasticate. | 3 - 42 3 - 42 |
0,9 ; 1,0 | The same, but in corrosive environments. |
GOST Р 51312-99 |
||||
Model | Design | Number of Strands | Wire Cross-Section, mm2 | Purpose of Use |
СБПБбШв | A signal and blocking cable with copper strands: insulated with PE, sheathed with PE, armored with two steel strips, jacketed in PVC plasticate hose. | 3 - 42 3 - 42 |
0,9 ; 1,0 | For installation in ducts, tunnels, manifolds, in plastic pipelines. For burying in soil when cable is not exposed to significant tensile force. |
GOST Р 51312-99 |
||||
Model | Design | Number of Strands | Wire Cross-Section, mm2 | Purpose of Use |
СБЗПБбШв | The same cable and also with water-blocking cable core filling. | 3 - 42 3 - 42 |
0,9 ; 1,0 | The same, but in high humidity. |
GOST Р 51312-99 | ||||
Model | Design | Number of Strands | Wire Cross-Section, mm2 | Purpose of Use |
СБПВГ | A signal and blocking cable with copper strands: insulated with PE, sheathed with PE and armored with two steel strips. | 3 - 42 3 - 42 |
0,9 ; 1,0 | For installation in ducts, in places where cable may be exposed to mechanical impact, but not to tensile force. |
GOST Р 51312-99 | ||||
Model | Design | Number of Strands | Wire Cross-Section, mm2 | Purpose of Use |
СБПВГ | A signal and blocking cable with copper strands: insulated with PE, sheathed with PE and armored with two steel strips. | 3 - 42 3 - 42 |
0,9 ; 1,0 | For installation in ducts, in places where cable may be exposed to mechanical impact, but not to tensile force. |
GOST Р 51312-99 | |||||
Model | Design | Number of Strands | Wire Cross-Section, mm2 | Operating voltage | Purpose of Use |
СБПБбШп | The same and also sheathed with PE material, armored with two steel strips, jacketed in PE hose. | 3 - 42 3 - 42 |
0,9 ; 1,0 | 380 V AC, 50 Hz or 700 V DC. | For installation in plastic pipelines. For burying in soil where cable may be exposed to mechanical impact, but not to tensile force. |
GOST Р 51312-99 | ||||
Model | Design | Number of Strands | Wire Cross-Section, mm2 | Purpose of Use |
СБЗПБ | The same cable and also with water-blocking cable core filling. | 3 - 42 3 - 42 |
0,9 ; 1,0 | The same, but in high humidity. |
GOST Р 51312-99 | |||||
Model | Design | Number of Strands | Wire Cross-Section, mm2 | Operating voltage | Purpose of Use |
СБЗПБГ | A signal and blocking cable with copper strands: insulated with PE, sheathed with PE, armored with two steel strips, and also with water-blocking cable core filling. | 3 - 42 3 - 42 |
0,9 ; 1,0 | 380 V AC, 50 Hz or 700 V DC. | For installation in ducts, in places where cables may be exposed to mechanical impact, but not to insignificant tensile force, and also in high humidity with level 0.9-1.0. |
GOST Р 51312-99 | |||||
Model | Design | Number of Strands | Wire Cross-Section, mm2 | Operating voltage | Purpose of Use |
СБПу | A signal and blocking cable with copper strands: insulated with PE, thick sheathed with PE. | 3 - 42 3 - 42 |
0,9 ; 1,0 | 380 V AC, 50 Hz or 700 V DC. | For installation in plastic pipelines. For burying in soil in corrosive environments without mechanical impact. |
GOST Р 51312-99 | ||||
Model | Design | Number of Strands | Wire Cross-Section, mm2 | Purpose of Use |
СБЗПу | The same cable and also with water-blocking cable core filling. | 3, 4, 5, 12, 16, 30, 33, 42 | 0,9 ; 1,0 | The same, but in high humidity. |
GOST Р 51312-99 | |||||
Model | Design | Number of Strands | Wire Cross-Section, mm2 | Operating voltage | Purpose of Use |
СБЗПУ(Э) | The same cable and also (shielded) with water-blocking cable core filling . | 3 - 42 3 - 42 |
0,9 ; 1,0 | 380 V AC, 50 Hz or 700 V DC | The same, but in high humidity. |
GOST Р 51312-99 | |||||
Model | Design | Number of Strands | Wire Cross-Section, mm2 | Operating voltage | Purpose of Use |
СБЗПЭБпШп | A signal and blocking cable with copper strands: insulated with PE, sheathed with PE, shielded, armored with two steel strips, with corrosion protection, jacketed in a PVC hose, and also with water-blocking cable core filling. | 3 - 42 3 - 42 |
0,9 ; 1,0 | 380 V AC, 50 Hz or 700 V DC | For installation in ducts, tunnels, manifolds, in plastic pipelines. For burying in soil when cable is not exposed to significant tensile force, in high humidity. |