Fire-Resistant Power Cables

АВВГнг

Model Design Number of Strands Working Voltage Wire Cross-Section, mm 2 Purpose of Use
АВВГнг Fire-resistant PVC sheathed cable with aluminum wires and with PVC protective covering. Up to 5 0,66 kV 2,5-50,0

Used to transfer and distribute electric power in fixed units with nominal AC voltage which varies between 0.66 and 1.0 kV.

This type of cable is laid in cables duct systems, tunnels, indoors, on the walls of buildings and structures and out-doors.
1,0 kV 2,5-240,0

Cables are manufactured using low-smoke and fire-resistant plasticates and they are labeled with "LS" marking the following way: АВВГнг-LS, ВВГнг-LS, АВБбШвнг-LS, ВБбШвнг-LS.

ВВГнг

Model Design Number of Strands Working Voltage Wire Cross-Section, mm 2 Purpose of Use
ВВГнг Fire-resistant PVC sheathed cable with aluminum wires and with PVC protective covering. Up to 5 0,66 kV 1,5-50,0

Used to transfer and distribute electric power in fixed units with nominal AC voltage which varies between 0.66 and 1.0 kV.

This type of cable is laid in cables duct systems, tunnels, indoors, on the walls of buildings and structures and out-doors.
1,0 kV 1,5-240,0

Cables are manufactured using low-smoke and fire-resistant plasticates and they are labeled with "LS" marking the following way: АВВГнг-LS, ВВГнг-LS, АВБбШвнг-LS, ВБбШвнг-LS.

АВБбШвнг

Model Design Number of Strands Working Voltage Wire Cross-Section, mm 2 Purpose of Use
АВБбШвнг Armored cable with aluminum wires, with PVC insulation, AaPv protective covering (when twisted wires of the cable are wrapped with two galvanized steel strips and then the cable is placed inside the protective hose made from fire-resistant PVC plasticate). Up to 5 0,66 kV 2,5-50,0

Used to transfer and distribute electric power in fixed units with nominal AC voltage which varies between 0.66 and 1.0 kV.
This type of cable is laid in cables duct systems, tunnels, indoors, on the walls of buildings and structures and out-doors. It is allowed to be buried in soil.

1,0 kV 2,5-240,0

Cables are manufactured using low-smoke and fire-resistant plasticates and they are labeled with "LS" marking the following way: АВВГнг-LS, ВВГнг-LS, АВБбШвнг-LS, ВБбШвнг-LS.

ВБбШвнг

Model Design Number of Strands Working Voltage Wire Cross-Section, mm 2 Purpose of Use
ВБбШвнг Armored cable with copper wires, with PVC insulation, AaPv protective covering (when twisted wires of the cable are wrapped with two galvanized steel strips and then the cable is placed inside the protective hose made from fire-resistant PVC plasticate). Up to 5 0,66 kV 1,5-50,0

Used to transfer and distribute electric power in fixed units with nominal AC voltage which varies between 0.66 and 1.0 kV.
This type of cable is laid in cables duct systems, tunnels, indoors, on the walls of buildings and structures and out-doors. It is allowed to be buried in soil.

1,0 kV 1,5-240,0

Cables are manufactured using low-smoke and fire-resistant plasticates and they are labeled with "LS" marking the following way: АВВГнг-LS, ВВГнг-LS, АВБбШвнг-LS, ВБбШвнг-LS.