Fire-Resistant Control Cables

АКВВГнг

SТ ТОО 40379340-003-2011
Model Design Number of Strands Wire Cross-Section, mm 2 Purpose of Use
АКВВГнг Current conducting aluminum cable strands: insulated with PVC plasticate, twisted into concentric layers and sheathed with fire-resistant PVC plasticate. 4 - 61 2,5-6,0 Used for fixed connection to electrical devices and equipment, terminal blocks of electrical substations with nominal AC voltage up to 660 V and frequency up to 1000 Hz or DC voltage up to 1000 V. Laid indoors, ducts, tunnels, in corrosive environments, without significant mechanical impact on the cable.

Cables are manufactured using low-smoke and low-gas fire-resistant plasticates and they are labeled with "LS" marking the following way: АКВВГнг-LS, КВВГнг-LS, АКВБбШвнг-LS, КВБбШвнг-LS, АКВВГЭнг-LS, КВВГЭнг- LS.

КВВГнг

SТ ТОО 40379340-003-2011
Model Design Number of Strands Wire Cross-Section, mm 2 Purpose of Use
КВВГнг Current conducting copper cable strands: insulated with PVC plasticate, twisted into concentric layers and sheathed with fire-resistant PVC plasticate. 4 - 61 0,75-6,0 Used for fixed connection to electrical devices and equipment, terminal blocks of electrical substations with nominal AC voltage up to 660 V and frequency up to 1000 Hz or DC voltage up to 1000 V. Laid indoors, ducts, tunnels, in corrosive environments, without significant mechanical impact on the cable.

Cables are manufactured using low-smoke and low-gas fire-resistant plasticates and they are labeled with "LS" marking the following way: АКВВГнг-LS, КВВГнг-LS, АКВБбШвнг-LS, КВБбШвнг-LS, АКВВГЭнг-LS, КВВГЭнг- LS.

АКВВГЭнг

SТ ТОО 40379340-003-2011
Model Design Number of Strands Wire Cross-Section, mm 2 Purpose of Use
АКВВГЭнг Current conducting aluminum cable strands: insulated with PVC plasticate and twisted into concentric layers. Twisted strands are wrapped and shielded using aluminum foil. Cable sheath is made from fire-resistant PVC plasticate. 4 - 61 2,5-6,0 Laid indoors, ducts, tunnels without mechanical impact on the cable in corrosive environments and without the requirement to protect electrical circuits from exposure to external electric fields.

Cables are manufactured using low-smoke and low-gas fire-resistant plasticates and they are labeled with "LS" marking the following way: АКВВГнг-LS, КВВГнг-LS, АКВБбШвнг-LS, КВБбШвнг-LS, АКВВГЭнг-LS, КВВГЭнг- LS.

КВВГЭнг

SТ ТОО 40379340-003-2011
Model Design Number of Strands Wire Cross-Section, mm 2 Purpose of Use
КВВГЭнг Current conducting copper cable strands: insulated with PVC plasticate and twisted into concentric layers. Twisted strands are wrapped and shielded using aluminum foil. Cable sheath is made from fire-resistant PVC plasticate. 4 - 61 0,75-6,0 Laid indoors, ducts, tunnels without mechanical impact on the cable in corrosive environment and without needs to protect electrical circuits from exposure to external electric fields.

Cables are manufactured using low-smoke and low-gas fire-resistant plasticates and they are labeled with "LS" marking the following way: АКВВГнг-LS, КВВГнг-LS, АКВБбШвнг-LS, КВБбШвнг-LS, АКВВГЭнг-LS, КВВГЭнг- LS.

АКВБбШвнг

SТ ТОО 40379340-003-2011
Model Design Number of Strands Wire Cross-Section, mm 2 Purpose of Use
АКВБбШвнг Current-conducting aluminum cable strands: insulated with PVC plasticate and twisted into concentric layers. Twisted strands are wrapped and armored using two galvanized steel strips. Cable sheath is made from fire-resistant PVC plasticate. 4 - 61 2,5-6,0 Used for fixed connection to electrical devices and equipment, terminal blocks of electrical substations with nominal AC voltage up to 660 V and frequency up to 1000 Hz or DC voltage up to 1000 V. Laid indoors, ducts, tunnels. Buried in soil (tranches) in corrosive environments and in places exposed to earth currents, when cables are not exposed to tensile stress.

Cables are manufactured using low-smoke and low-gas fire-resistant plasticates and they are labeled with "LS" marking the following way: АКВВГнг-LS, КВВГнг-LS, АКВБбШвнг-LS, КВБбШвнг-LS, АКВВГЭнг-LS, КВВГЭнг- LS.

КВБбШвнг

SТ ТОО 40379340-003-2011
Model Design Number of Strands Wire Cross-Section, mm 2 Purpose of Use
КВБбШвнг Current-conducting copper cable strands: insulated with PVC plasticate and twisted into concentric layers. Twisted strands are wrapped and armored using two galvanized steel strips. Cable sheath is made from fire-resistant PVC plasticate. 4 - 61 0,75-6,0 Used for fixed connection to electrical devices and equipment, terminal blocks of electrical substations with nominal AC voltage up to 660 V and frequency up to 1000 Hz or DC voltage up to 1000 V. Laid indoors, ducts, tunnels. Buried in soil (tranches) in corrosive environments and in places exposed to earth currents, when cables are not exposed to tensile stress.

Cables are manufactured using low-smoke and low-gas fire-resistant plasticates and they are labeled with "LS" marking the following way: АКВВГнг-LS, КВВГнг-LS, АКВБбШвнг-LS, КВБбШвнг-LS, АКВВГЭнг-LS, КВВГЭнг- LS.